Schneider Electric has no immediate plan for updating the other identified software products. For other products listed, the updated ModbusDriverSuite will be implemented with each new version of those software products.
#POWERSUITE 2013 SERIAL PRO#
OFS V3.5 and Unity Pro V8 have been released including the updated ModbusDriverSuite.
#POWERSUITE 2013 SERIAL DRIVER#
Schneider Electric recommends that products that use this driver be updated with the latest version of software.
#POWERSUITE 2013 SERIAL HOW TO#
Schneider Electric has released a security notification with further information on this vulnerability and how to mitigate it: DIFFICULTYĪn attacker with a high skill would be able to exploit this vulnerability. No known public exploits specifically target this vulnerability. This vulnerability can be remotely exploited. A CVSS v2 base score of 9.3 has been assigned the CVSS vector string is (AV:N/AC:M/Au:N/C:C/I:C/A:C).CVSS Calculator,, web site last accessed March 27, 2014. This web site will be active sometime after publication of this advisory. has been assigned to this vulnerability. If a large buffer size is specified in this header, a stack-based buffer overflow results.Ī second overflow problem can then be exploited by overwriting the return address, allowing the attacker to execute arbitrary code with the permission of the user running the software.ĬVE-2013-0662NVD,, NIST uses this advisory to create the CVE web site report.

When a connection is made, the Modbus Application Header is first read into a buffer.

#POWERSUITE 2013 SERIAL SERIAL#
The Modbus Serial Driver creates a listener on Port 27700/TCP. STACK-BASED BUFFER OVERFLOWCWE-121: Stack-based Buffer Overflow,, web site last accessed March 27, 2014. VULNERABILITY CHARACTERIZATION VULNERABILITY OVERVIEW Schneider Electric estimates that these products are used primarily in China, United States, and Europe. According to Schneider Electric, the affected software is deployed across several sectors including Chemical, Critical Manufacturing, Dams, Energy, Food and Agriculture, Government Facilities, Nuclear Reactors, Materials, and Waste, and Transportation Systems. These applications rely on a common driver to communicate with PLCs. The affected products are mostly software-based utilities and engineering tools designed for programming and configuring process, machine, and general control applications. Schneider Electric corporate headquarters is located in Paris, France, and maintains offices in more than 100 countries worldwide.

NCCIC/ICS CERT recommends that organizations evaluate the impact of this vulnerability based on their operational environment, architecture, and product implementation. Impact to individual organizations depends on many factors that are unique to each organization. Modbus Serial Driver versions that are affected:Ī successful exploit of this vulnerability could cause a buffer overflow that could allow arbitrary code execution with user privileges.